Excessive Mould Plate Flatness Causes Flash on the Parts

E43-220 · Geometrical Tolerance Errors · Injection Mould Plate 600×600 · ★★

Problem Symptom

Plate flatness 0.05mm (allowable 0.02) let the moulding face gap and produced flash

Root Cause

[Mechanism] Grinding heat distortion and clamping made the middle of the plate concave.
[Calculation] A flatness of 0.05 opened a mould closing gap of 0.05 against the 0.02 allowable, so material flashed out.
[Design Omission] No grinding allowance was left and no flatness inspection was done; this design flaw caused the flash.

Correct Solution

1) Leave 0.1 of grinding allowance on the plate;
2) Inspect flatness ≤0.02;
3) Use separate rough and fine grinding passes with temperature control;
4) Tighten with even force;
5) Check the closing gap with a mould trial press;
6) Lap the mating faces;
7) Re-grind periodically;
8) Bring flatness into the acceptance criteria.

Checklist

References

GB/T 1182-2018 Geometrical Tolerances