Excessive Impeller Seat-to-Bearing Seat Coaxiality Causes Cavitation and Vibration

E43-222 · Geometrical Tolerance Errors · Centrifugal Pump Shaft ∅50 · ★★

Problem Symptom

Coaxiality between the impeller seat and the bearing seat 0.05mm (allowable 0.02) made the impeller strike the casing and cavitate

Root Cause

[Mechanism] The datum transfer between two setups left the two features non-coaxial.
[Calculation] A coaxiality of 0.05 offset the impeller by 0.05 against the 0.02 clearance, so it wore the casing and cavitated.
[Design Omission] The two locations were not ground in one setup; this design flaw caused the cavitation.

Correct Solution

1) Grind the impeller seat and the bearing seat in one setup;
2) Inspect coaxiality ≤0.02;
3) Unify the datum on the center holes;
4) Dynamically balance the impeller;
5) Check the clearance in a trial rotation;
6) Measure the vibration ≤2.8;
7) Re-check the fits;
8) Bring coaxiality into the process specification.

Checklist

References

GB/T 1182-2018 Geometrical Tolerances