E43-224 · Geometrical Tolerance Errors · Pneumatic Slide Rail · ★★
Rail symmetry 0.06mm (allowable 0.02) jammed the slide
[Mechanism] The two sides were machined from non-coincident datums and became asymmetric.
[Calculation] A symmetry of 0.06 gave a single-side clearance of 0.06 against the 0.02 allowable, so the slide jammed.
[Design Omission] The two sides were not machined in one setup; this design flaw caused the jamming.
1) Machine the two sides in one setup;
2) Inspect symmetry ≤0.02;
3) Unify the datum;
4) Match the slide to the rails;
5) Verify smooth sliding in a trial;
6) Deburr;
7) Provide lubrication grooves;
8) Bring symmetry into the process inspection.
GB/T 1182-2018 Geometrical Tolerances