E43-226 · Geometrical Tolerance Errors · Offset Printing Press Plate Cylinder ∅300 · ★★★
Cylinder total runout 0.06mm (allowable 0.02) caused colour misregistration
[Mechanism] The eccentricity of each section added up into the total runout.
[Calculation] A total runout of 0.06 shifted the plate circumferentially by 0.06×π/2≈0.09mm against the 0.02 registration allowance.
[Design Omission] The cylinder was not straightened and the total runout was not inspected; this design flaw caused the misregistration.
1) Straighten the cylinder to a total runout ≤0.02;
2) Unify the datum on the two center holes;
3) Rough and finish turn in one setup;
4) Inspect the total runout;
5) Select P5 bearings;
6) Check the registration with a trial print;
7) Re-verify periodically;
8) Bring total runout into the acceptance criteria.
GB/T 1182-2018 Geometrical Tolerances