E43-235 · Geometrical Tolerance Errors · Hydraulic Directional Valve Spool Plate · ★★

Problem Symptom

Spool plate mating face flatness 0.04mm (allowable 0.015) caused internal leakage

Root Cause

[Mechanism] Grinding heat distortion made the middle of the spool plate concave.
[Calculation] A flatness of 0.04 opened a joint gap of 0.04 against the 0.015 allowable, so the pressure oil leaked internally.
[Design Omission] No grinding allowance was left and the flatness was not inspected; this design flaw caused the internal leakage.

Correct Solution

1) Leave 0.08 of grinding allowance on the spool plate;
2) Inspect flatness ≤0.015;
3) Use separate rough and fine grinding passes with temperature control;
4) Apply sealing gaskets;
5) Tighten the bolts with even force;
6) Perform a pressure-holding leak test;
7) Re-grind periodically;
8) Bring flatness into the acceptance criteria.