Excessive Flange Hole Position Causes Vacuum Leakage

E43-238 · Geometrical Tolerance Errors · Semiconductor Vacuum Chamber Flange CF300 · ★★★

Problem Symptom

Flange hole position Φ0.4mm (allowable Φ0.15) caused the seal to leak

Root Cause

[Mechanism] The division error of the machining center let the hole positions drift.
[Calculation] A position tolerance of Φ0.4 shifted the holes by 0.4 against the 0.15 seal ring, so the vacuum leaked.
[Design Omission] No drilling jig was used and the position tolerance was not inspected; this design flaw caused the leak.

Correct Solution

1) Keep the machining center locating accuracy ≤0.05;
2) Inspect the position tolerance ≤Φ0.15;
3) Drill the seal rings as a matched set;
4) Perform a helium leak check on the first piece;
5) Deburr;
6) Tighten the bolts with even force;
7) Perform a vacuum pressure-holding test;
8) Bring position tolerance into the mandatory inspection list.

Checklist

References

GB/T 1182-2018 Geometrical Tolerances