Problem Symptom

Height accumulation across three pedestals reached 0.12mm; the shaft bent and vibrated; 9 line stops per month

Root Cause

[Height Chain] The bottom faces of the three bearing pedestals were machined to ±0.05, accumulating to ±0.15; the actual non-coaxiality was 0.12mm.
[Bending] The shaft spans 1.5m and, with pedestal height differences, developed deflection; the additional bending moment caused vibration.
[Design Omission] A common datum face should be used for machining, coaxiality should be specified, and no on-site scraping and levelling was done.

Correct Solution

1) Machine the pedestal bottom faces from a common datum face to prevent accumulation;
2) Specify coaxiality ≤0.02 to guarantee alignment;
3) Scrape and level on site so the height difference is ≤0.02 and prevent uneven loading;
4) Tighten the pedestal height tolerance to ±0.02 to improve assembly;
5) Laser-align the shafting to reduce vibration;
6) Add an intermediate auxiliary support to reduce deflection;
7) Measure vibration ≤1.8mm/s in the trial run to verify smooth running;
8) Bring coaxiality into the installation acceptance criteria.

Checklist

References

GB/T 1182-2018 Geometrical Product Specifications (GPS) — Geometrical Tolerances