E43-065 · Dimension Chain Stack-up Out of Tolerance · Horizontal Machining Center Spindle Box · ★★★
Accumulated error in the transmission chain made the gear backlash -0.02 (negative); meshing seized and a tooth broke
[Cumulative Error] The housing hole spacing tolerance of ±0.03 accumulated, so the center distance became too small and the backlash went negative.
[Seizure] With backlash j<0 the gears had no meshing clearance, so the mechanism bound during running and a tooth broke.
[Design Omission] A center distance dimension chain should have been calculated with positive backlash reserved, and no final-assembly mesh inspection was done.
1) Calculate the center distance dimension chain to prevent exceedance;
2) Reserve positive backlash of 0.06~0.12 to prevent seizing;
3) Tighten the hole spacing tolerance to improve assembly;
4) Inspect the housing on a CMM 100%;
5) Check the mesh contact pattern after final assembly;
6) Calculate the backlash from j=Σ;
7) Run in the first piece to verify free movement;
8) Repair out-of-specification bores by re-boring.
GB/T 5847-2004 Dimension Chains