Machine Tool Column Multi-Segment Height Accumulation

E43-455 · Dimensional-Chain Accumulation · 3 stacked column segments designed 3000±0.1, measured 3001.2 after stacking · ★★

Problem Description

Accumulated segment heights made the total height 1.2mm out of tolerance and tilted the table.

Root Cause

[Mechanism] Segment height tolerances accumulated so the closed loop (total height) went out of tolerance.
[Calculation] T0=ΣTi=3×0.4=1.2, 12× the 0.1 allowance.
[Design Omission] No adjusting shims or match-machining; design defect → total height out of tolerance.

Corrective Solution

1) Provide a shim to absorb accumulation;
2) Match-grind each section per T0/√3;
3) Unify the datum face;
4) Probability method verification;
5) Selective matching by measurement;
6) Leave grinding stock;
7) Straightedge height check;
8) First-article height measured ≤0.1.

Checklist

Reference

GB/T 5847-2004 Dimensional chain — Calculation method