MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Tolerance and Fit Error Case › Welded Multi-Segment Length Accumulation

Welded Multi-Segment Length Accumulation

E43-460 · Dimensional-Chain Accumulation · Frame of 4 welded segments designed length 4000±1, measured 4005 · ★★

Problem Description

Accumulated weld shrinkage across segments made overall length 5mm out of tolerance, causing assembly deviation.

Root Cause

[Mechanism] Weld shrinkage across segments was not reserved, so the closed loop (overall length) accumulated out of tolerance.
[Calculation] T0=Σ(shrinkage+tolerance)=4×1.25=5, 5× the 1 allowance.
[Design Omission] Shrinkage and match-machining not reserved; design defect → overall length out of tolerance.

Corrective Solution

1) Reserve shrinkage allowance on each segment;
2) Use a jig to control overall length;
3) Symmetrical welding to reduce deviation;
4) Selective matching by measurement;
5) Straighten after welding;
6) Statistical check;
7) Measure length by wire line;
8) First-article length measured ≤1.

Checklist

Reference

GB/T 50205-2020 Standard for acceptance of construction quality of steel structures

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL