E43-469 · Dimensional-Chain Accumulation · Truss node position designed ±1, measured ±5 after 8 members · ★★
Accumulated member cutting and welding made node position 5mm out of tolerance, tilting the whole structure.
[Mechanism] The multi-member length dimensional chain accumulated, so the closed loop (node position) went out of tolerance.
[Calculation] T0=ΣTi=8×0.6≈5, 5× the 1 allowance.
[Design Omission] Shrinkage and match-machining not reserved; design defect → node out of tolerance.
1) Reserve shrinkage allowance on members;
2) Use a jig to control nodes;
3) Symmetrical welding to reduce deviation;
4) Selective matching by measurement;
5) Straighten after welding;
6) Statistical check;
7) Total-station check;
8) First-article node measured ≤1.
GB/T 50205-2020 Standard for acceptance of construction quality of steel structures