Multi-Part Valve Stroke Accumulation

E43-474 · Dimensional-Chain Accumulation · Valve stroke designed 50±0.2, measured 52.3 after 5 parts · ★★

Problem Description

Stem + disc accumulation made stroke 2.3mm out of tolerance, shifting the seal.

Root Cause

[Mechanism] Multi-part axial dimensional chain accumulated, so the closed loop (stroke) went out of tolerance.
[Calculation] T0=ΣTi=5×0.46≈2.3, 11.5× the 0.2 allowance.
[Design Omission] No adjustment or match-machining; design defect -> stroke out of tolerance.

Corrective Solution

1) Provide a shim to absorb accumulation;
2) Match-machine each part per T0/√5;
3) Unify the datum;
4) Statistical check;
5) Selective matching by measurement;
6) Leave grinding stock;
7) Travel gauge check;
8) First-article travel measured ≤0.2.

Checklist

Reference

GB/T 12224-2015 Steel valves — General requirements