E43-481 · Dimensional-Chain Accumulation · Truck crane 3-section boom reach designed 10000±2, measured 10015 · ★★
Multi-section boom gap accumulation made reach 15mm out of tolerance, shifting placement.
[Mechanism] Multi-section slide-block gap chain accumulated, so the closed loop (reach) went out of tolerance.
[Calculation] T0=√(3×8.7²)=15, 7.5× the 2 allowance.
[Design Omission] No adjustment or match-machining; design defect → reach out of tolerance.
1) Provide a shim to absorb accumulation;
2) Match-machine each section per T0/√3;
3) Unify the datum;
4) Statistical check;
5) Selective matching by measurement;
6) Leave grinding stock;
7) Distance meter check;
8) First-article reach measured ≤2.
GB/T 3811-2008 Design rules for cranes