Knowledge Base › Tolerance and Fit Error Case › Gauge Fixture Different-Datum Mismatch

Gauge Fixture Different-Datum Mismatch

E43-518 · Datum Non-Coincidence · A gauge checking on end face A while designed to use face B as datum, misjudgment 0.08 · ★★

Problem Description

The gauge datum did not coincide with the design datum, causing conforming parts to be misjudged as 0.08mm out of tolerance.

Root Cause

[Mechanism] The gauge datum and design datum do not coincide, so the datum offset feeds into the measurement.
[Calculation] Datum non-coincidence error = A-to-B error 0.08, 4× the gauge tolerance of 0.02.
[Design Omission] The gauge was not built to the design datum; design defect → misjudgment.

Corrective Solution

1) Rebuild the gauge on the design datum;
2) Unify datum symbols;
3) Tolerance-allocate by datum offset;
4) Re-measure first articles on the design datum;
5) Note it in the process sheet;
6) Reduce datum transfers;
7) Gauge calibration;
8) First-article measured ≤0.02.

Checklist

Reference

GB/T 1182-2018 GPS — Geometrical tolerancing (form, orientation, location and run-out)

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »