Casting Parting-Line Datum Mismatch

E43-520 · Datum Non-Coincidence · A casting based on the parting line while designed to use the center as datum, 2 off · ★★

Problem Description

The casting parting-line datum and the design center do not coincide, leaving the machining allowance 2mm off.

Root Cause

[Mechanism] The parting line and the center datum do not coincide, so mold shift feeds into the center offset.
[Calculation] Datum non-coincidence error = mold shift 2, 2× the allowance tolerance of 1.
[Design Omission] The center was not used as the datum; design defect → allowance off.

Corrective Solution

1) Use the center (process boss) as the datum;
2) Provide closing pins to control mold shift;
3) Unify datum callouts;
4) Allocate allowance by datum offset;
5) First-article layout inspection;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article allowance measured ≤1.

Checklist