MOULDLKnowledge Base3D Model DownloadsMembership
中文版Model Store »
HomeModels
Table of contents

Knowledge Base Home

📐 Standard Data

🧮 Calculators

📖 Selection Guides

🏭 Material Grades

❓ Engineer FAQ

🗂 Quick-Reference Categories

❌ Error Case Studies

📚 Technical Articles

Knowledge Base › Tolerance and Fit Error Case › Spline Outer-Diameter vs Pitch-Circle Datum Mismatch

Spline Outer-Diameter vs Pitch-Circle Datum Mismatch

E43-522 · Datum Non-Coincidence · A spline located on the outer diameter while designed to use the pitch circle as datum, tooth pitch 0.03 over tolerance · ★★

Problem Description

The outer-diameter location and the design pitch-circle datum do not coincide, leaving the spline tooth pitch 0.03mm out of tolerance.

Root Cause

[Mechanism] The outer diameter and the pitch-circle datum do not coincide, so outer-diameter runout feeds into the tooth pitch.
[Calculation] Datum non-coincidence error = outer-diameter runout 0.03, 1.5× the tooth-pitch tolerance of 0.02.
[Design Omission] The pitch circle was not used as the datum; design defect → tooth pitch out of tolerance.

Corrective Solution

1) Use the pitch circle (broaching) as the datum;
2) Keep the outer-diameter runout small;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) First-article pitch measurement;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article pitch measured ≤0.02.

Checklist

Reference

GB/T 1144-2001 Straight-sided splines — dimensions, tolerances and inspection

Related model download:Understood the principle and ready to try?Go to MOULDL to download related 3D models and CAD drawings for free »
MOULDL · Mechanical Engineering Knowledge Base · free self-study reference for machine designers, 3D CAD models at MOULDL