Knowledge Base › Tolerance and Fit Error Case › Compressor-to-Cylinder-Bore Datum Misalignment

Compressor-to-Cylinder-Bore Datum Misalignment

E43-538 · Datum Misalignment · Compressor located on the cylinder OD while the design references the bore, causing a 0.06 overshoot · ★★

Problem Description

The cylinder-OD datum does not coincide with the design cylinder bore, so the piston clearance exceeds tolerance by 0.06mm.

Root Cause

[Mechanism] The cylinder-OD datum does not coincide with the bore, so OD runout is carried into the cylinder bore.
[Calculation] The datum misalignment error is an OD runout of 0.06, which is 3 times the clearance allowance of 0.02.
[Design Omission] The cylinder bore is not used as the datum; this design flaw leads to clearance out-of-tolerance.

Corrective Solution

1) Use the cylinder bore as the locating datum;
2) Control OD runout;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Measure clearance on the first article;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article clearance measured ≤0.02.

Checklist

Reference

GB/T 1182-2018 GPS — Geometrical tolerancing (form, orientation, location and run-out)