E43-549 · Datum Misalignment · Hydraulic cylinder located on the bottom while the design references the guide bushing, causing a 0.05 overshoot · ★★
The cylinder-bottom datum does not coincide with the design guide-bushing datum, so the piston guidance deviates by 0.05mm.
[Mechanism] The cylinder-bottom datum does not coincide with the guide-bushing datum, so the bottom perpendicularity error is carried into the guidance.
[Calculation] Datum mismatch error = bottom perpendicularity error of 0.05, which is 2.5 times the guidance allowance of 0.02.
[Design Omission] The guide bushing was not used as the datum; this design flaw leads to guidance overshoot.
1) Use the guide bushing as the locating datum;
2) Control the cylinder-bottom perpendicularity;
3) Unify datum callouts;
4) Tolerance-allocate by datum offset;
5) Measure the guidance on the first article;
6) Note it in the process sheet;
7) Reduce datum transfers;
8) First-article guidance ≤ 0.02.
GB/T 28781-2012 Hydraulic presses — Hydraulic cylinder specifications