E43-024 · Tolerance Callout & Grade Errors · Bearing Housing Bore · ★★
Φ80H7 was mis-typed as Φ80h7, making the bore 0.035 too small; the bearing was crushed during pressing
[Wrong Designation] The hole was specified h7 (shaft-basis clearance) instead of H7 (hole-basis), and the measured bore Φ80(-0.022/0) was 0.035 smaller than the bearing outer ring.
[Crushing] The forced press fit split the housing bore and deformed the bearing outer ring.
[Design Omission] Fit designations were not proof-read, the hole-basis principle was confused, and the drawing review missed it.
1) Correct the housing bore to Φ80H7 to match the bearing outer ring;
2) Establish a fit designation proof-reading checklist to prevent mis-typing;
3) Apply three-level drawing review to prevent wrong fit callouts;
4) Measure the bearing outer ring and match it to guarantee the clearance;
5) Measure bore and shaft dimensions before assembly to prevent wrong fitting;
6) Monitor press force to guard against insufficient interference;
7) Verify assembly on the first piece to confirm correct seating;
8) Bring fit designation proof-reading into drawing review.
GB/T 1800.2-2020 Limits and Fits — Standard Tolerances