E43-565 · Wrong Tolerance Callout and Grade · Slider's two guideway faces drawn parallelism 0.03 without specifying the tolerance-zone direction, causing inconsistent inspection interpretation · ★
The parallelism did not specify the tolerance-zone width direction; inspection took different directions and batch verdicts were inconsistent.
[Mechanism] The parallelism tolerance zone is the distance between two parallel planes, its direction set by the datum; an unclear callout left inspection orientations inconsistent.
[Calculation] Measured 0.02 along the face normal but 0.05 along the projection direction; the same part got two verdicts, causing an overshoot dispute.
[Design Omission] The parallelism tolerance-zone direction was not made explicit; this design flaw causes inconsistent verdicts.
1) Make datum face A and the tolerance-zone normal explicit for the parallelism;
2) Per GB/T 1182, orient the tolerance zone perpendicular to the datum;
3) Unify the inspection direction along the face normal;
4) Measure the first article in the specified direction;
5) Define the datum and direction on the CMM;
6) Keep the drawing datum clear and singular;
7) Measure with a direction-fixed gauge;
8) Re-inspect to verify consistency.
GB/T 1182-2018 Geometrical tolerancing—Form, orientation, location and run-out