E43-567 · Tolerance Specification and Grade Error · A hole pattern whose locating dimension 100 carries ±0.1 while also being dimensioned with position tolerance ∅0.2, causing repeated and conflicting true dimensions · ★★
A locating dimension is not boxed and still carries a tolerance, creating a double constraint with the position tolerance that conflicts during inspection and causes overshoot.
[Mechanism] The theoretically exact dimension (TED) for a position tolerance must be boxed and carry no tolerance. Retaining ±0.1 by mistake creates a dimension chain that double-constrains and conflicts with the position tolerance.
[Calculation] The ±0.1 dimensional tolerance and the ∅0.2 position tolerance coexist; the allowed zone of ∅0.2 is further cut by ±0.1, shrinking the acceptable area.
[Design Omission] The theoretically exact dimension is not boxed and still carries a tolerance; design defect → double-constraint conflict.
1) Box the locating dimension and mark 100 as a theoretically exact dimension;
2) Delete the ± tolerance from the boxed dimension;
3) Control location solely by the ∅0.2 position tolerance;
4) Per GB/T 1182, boxed dimensions carry no tolerance;
5) On the first article, measure per the position tolerance;
6) Clean up duplicated tolerances on the drawing;
7) Build gauges to the theoretically exact dimensions;
8) Verify position tolerance on a CMM.
GB/T 1182-2018 Geometrical product specifications (GPS) — Form, orientation, location and run-out tolerances