E43-570 · Tolerance Specification and Grade Error · A hole pattern designed with a composite position tolerance of upper cell ∅0.5 and lower cell ∅0.1, misread as independent cells and causing wrong datum constraints · ★★
The meaning of the upper and lower cells of a composite position tolerance is confused, leading to wrong judgment of both the hole pattern relative to datum and the within-pattern consistency.
[Mechanism] The upper cell of a composite position tolerance controls the hole pattern's location relative to datum, while the lower cell controls the mutual location of holes within the pattern. Misreading them inverts the constraint hierarchy.
[Calculation] The upper cell ∅0.5 controls pattern location and the lower cell ∅0.1 controls hole spacing; when read as independent cells, a within-pattern value of 0.3 is wrongly judged acceptable, though it actually exceeds the lower-cell 0.1.
[Design Omission] The composite frame hierarchy is misapplied; design defect → within-pattern consistency overshoot.
1) Clarify that the upper composite cell controls pattern location and the lower cell controls within-pattern location;
2) Follow the composite position tolerance rules of GB/T 13319;
3) The lower-cell datum references only orientation, not location;
4) Verify with gauges at two levels;
5) On the first article, measure within-pattern hole spacing and pattern location;
6) Evaluate layer by layer on a CMM;
7) Annotate the frame hierarchy on the drawing;
8) Verify by trial pin insertion during assembly.
GB/T 13319-2020 Geometrical product specifications (GPS) — Position tolerancing