E43-587 · Tolerance Annotation and Grade Error · A P4 precision bearing housing ∅62 where the drawing called K7 but K6 should have been selected for P4, causing the fit interference to exceed tolerance and generate heat · ★★★
The precision-bearing housing bore tolerance band was not upgraded with the bearing precision; K7 was too loose / locally over-interfered, causing heat during rotation.
[Mechanism] The housing bore tolerance band must be selected according to the bearing precision class; a P4 precision bearing requires a tighter bore band, and misusing the ordinary K7 leads to an improper fit.
[Calculation] The P4 bearing outer-diameter tolerance is ±0.008, so a K6 (0.019) bore should be paired with it; misusing K7 (0.030) lets the interference fluctuate by up to 0.03, exceeding the allowable 0.01.
[Design Omission] The housing bore tolerance band was not upgraded with the bearing precision; this design defect leads to heat generation.
1) Change the P4 bearing housing bore to K6 to match the precision;
2) Follow the precision-bearing fit table in GB/T 307.3;
3) Control bore roundness to ≤0.005 to prevent local interference;
4) On the first article, measure bore diameter and roundness;
5) Annotate the fit on the drawing in line with the bearing precision class;
6) Finish-bore and hone to maintain bore precision;
7) After assembly, measure the clearance;
8) During running, measure the temperature rise.
GB/T 307.3-2017 Rolling bearings — General technical specifications