E43-592 · Tolerance Annotation and Grade Error · Bearing bores at both ends of a pump body where the design marked concentricity ∅0.02 but omitted the common datum, leaving the evaluation datum undefined · ★★
The concentricity between two holes lacked a common datum; with no reference axis, the shaft bound from eccentricity after assembly.
[Mechanism] Two-hole concentricity must reference a common axis or one of the holes as a datum; omitting the datum leaves the evaluation basis undefined, so concentricity cannot be measured.
[Calculation] Without a datum, each hole passes individually but their relative eccentricity reaches 0.05; after the shaft is installed, bending and binding occur, exceeding the allowable 0.02.
[Design Omission] The common datum was omitted from the two-hole concentricity callout; this design defect leads to eccentric binding.
1) Annotate the concentricity with the common datum A-B (the common axis of the two holes);
2) Alternatively, take one hole as the datum and mark the other for concentricity;
3) Follow the concentricity datum rules in GB/T 1182;
4) On the first article, trial-pass a boring bar and measure concentricity;
5) Complete the datum references on the drawing;
6) Bore both holes in one setup to maintain concentricity;
7) Measure the two hole axes on the CMM;
8) Install the shaft and verify rotation.
GB/T 1182-2018 Geometrical tolerancing—Form, orientation, location and run-out