E43-594 · Tolerance Annotation and Grade Error · A shaft keyway where the design marked symmetry 0.02 but omitted the datum axis, causing keyway eccentricity and eccentric load on the key · ★★
The keyway symmetry lacked the datum axis; the slot was eccentric by 0.05, and the key was crushed by unilateral eccentric load.
[Mechanism] Keyway symmetry must reference the axis datum; omitting it leaves symmetry evaluation without a basis, and slot eccentricity puts the key under eccentric load.
[Calculation] Without a datum, the slot is eccentric by 0.05; the key sides are loaded unevenly, doubling the unilateral pressure and exceeding the allowable side crush.
[Design Omission] The datum axis was omitted from the symmetry callout; this design defect leads to eccentric crushing of the key.
1) Annotate symmetry with datum A (the axis);
2) Follow the symmetry datum rules in GB/T 1182;
3) Control the two keyway sides symmetrically about the axis to 0.02;
4) On the first article, measure slot symmetry;
5) Complete the datum references on the drawing;
6) Use indexed fixturing to maintain symmetry;
7) Check key-side contact with blued layout fluid;
8) After assembly, measure the load on the key.
GB/T 1182-2018 Geometrical tolerancing—Form, orientation, location and run-out