E43-597 · Tolerance Annotation and Grade Error · An end-face disk where the design marked circular runout when end-face total runout should have been called, leaving axial flatness uncontrolled and the sealing face warped · ★★
The end face was incorrectly marked for circular runout, which controls only a single circle; axial total runout was uncontrolled, the face warped by 0.08, and the seal leaked.
[Mechanism] End-face circular runout controls only one circle, whereas end-face total runout controls the entire face axially; misapplying it leaves face warpage unconstrained.
[Calculation] Single-circle runout of 0.02 passes, but measured total runout over the whole face is 0.08 (including warpage); the 0.08 local gap on the sealing face causes leakage.
[Design Omission] Circular runout was misapplied on the end face instead of total runout; this design defect leads to face warpage and leakage.
1) Change the end-face callout to end-face total runout 0.03 to control the whole face;
2) Per GB/T 1182, total runout constrains the entire feature;
3) Take datum A as the axis;
4) On the first article, measure end-face total runout;
5) Check the runout type on the drawing;
6) Turn the end face in one setup to keep it flat;
7) Check face contact with blued layout fluid;
8) Pressure-test to verify sealing.
GB/T 1182-2018 Geometrical tolerancing—Form, orientation, location and run-out