Knowledge Base › Tolerance and Fit Error Case › Oversize Spline Flank Wearing and Increasing Backlash

Oversize Spline Flank Wearing and Increasing Backlash

E43-616 · Surface roughness mismatched with the fit · A transmission spline flank designed Ra1.6 but measured Ra6.3, flank wear grows, backlash increases and shocks torque transmission · ★★

Problem Description

The spline flank at Ra6.3 is too rough; under reversal shocks it wears, flank clearance grows, and torque transmission becomes noisy.

Root Cause

[Mechanism] Spline flanks transmit torque through contact; on an oversize surface the peaks wear under reversal fretting, flank clearance grows, and shock loads are amplified.
[Calculation] Rz≈31μm; fretting wear erodes the flank about 0.02mm/month, so in six months the clearance grows from 0.03 to 0.15, causing shock.
[Design Omission] The spline flank is too rough, a design defect → wear and shock.

Corrective Solution

1) Grind/pull-broach the spline flanks to Ra0.8~1.6;
2) Follow the spline surface requirements per GB/T 1144;
3) Carburize and quench the flanks for hardness;
4) On the first article, verify flank Ra;
5) Specify Ra on the spline flanks in the drawing;
6) Finish-machine the centering surface;
7) Use grease to reduce fretting;
8) Verify flank clearance on an endurance test.

Checklist

Reference

GB/T 1144-2001 Rectangular splines — Dimensions, tolerances and verification