E43-622 · Surface roughness mismatched with the fit · A mold water passage designed Ra6.3 but measured Ra25, flow resistance rises, scaling accelerates, cooling efficiency drops and deformation results · ★
The passage wall at Ra25 is too rough; flow resistance rises and flow drops, scaling accelerates, and uneven cooling deforms the mold.
[Mechanism] An oversize cooling passage increases flow resistance and provides attachment sites for scale, reducing flow and heat transfer, so cooling is uneven and the mold deforms.
[Calculation] Oversize roughness raises the friction factor about 30%, reducing flow and heat-transfer coefficient; uneven mold temperature causes out-of-tolerance part deformation.
[Design Omission] The water passage roughness was not controlled, a design defect → uneven cooling and deformation.
1) Hone/burnish the passage after drilling to Ra6.3;
2) Set passage Ra per cooling requirements;
3) Apply corrosion and scale-resistant treatment to the passage;
4) On the first article, verify flow and mold temperature;
5) Specify passage Ra on the drawing;
6) Periodically descale during maintenance;
7) Optimize the flow path to reduce resistance;
8) Verify part deformation.
GB/T 131-2006 Geometrical product specifications — Surface texture designation