E43-625 · Surface roughness mismatched with the fit · A plunger-pump piston ∅18 designed Ra0.1 but measured Ra0.4, internal leakage at the fit drops volumetric efficiency and flow is insufficient · ★★★
The piston pair at Ra0.4 is too rough; under high pressure clearance leakage grows, volumetric efficiency drops from 95% to 80%, and flow is insufficient.
[Mechanism] The piston and bore seal high pressure through a micron clearance; oversize peaks and valleys add effective clearance, and high-pressure leakage lowers volumetric efficiency.
[Calculation] Leakage ∝ clearance³; the effective clearance at Ra0.4 exceeds that at Ra0.1, volumetric efficiency drops from 95% to 80%, and flow falls 15% short.
[Design Omission] The piston pair is too rough, a design defect → low volumetric efficiency.
1) Lap the piston and bore to Ra0.05~0.1;
2) Specify superfinished surfaces per pump accuracy;
3) Select-mate to an 8~12μm clearance;
4) On the first article, verify Ra and volumetric efficiency;
5) Specify Ra0.1 on the drawing;
6) Lap-fit to preserve cylindricity;
7) Assemble clean;
8) Measure flow and efficiency on a test rig.
GB/T 131-2006 Geometrical product specifications — Surface texture designation