E43-639 · Surface Roughness Mismatch with Fit · A pneumatic valve seat cone designed Ra0.4 but measured Ra1.6, causing a discontinuous sealing line and seat leakage with pressure drop · ★★
The valve-seat sealing cone is too rough at Ra1.6; the sealing line is discontinuous, and closing leaks cause system pressure drop.
[Mechanism] The seat and poppet seal along a cone line; excessive roughness peaks and valleys break the sealing line, so it still leaks when closed and pressure cannot hold.
[Calculation] At Ra1.6 residual leakage paths remain along the sealing line; the closed leak rate exceeds the allowable value, and system pressure drops past the limit within minutes.
[Design Omission] The seat cone was left too rough; this design defect causes sealing-line leakage.
1) Lap the seat cone to Ra0.2~0.4;
2) Match-lap poppet and seat;
3) Set cone angle and Ra by sealing requirements;
4) Measure Ra and pressure-hold on the first article;
5) Call out cone-face Ra on the drawing;
6) Deburr and clean;
7) Match seat hardness;
8) Verify with a pressure-hold test.
GB/T 131-2006 Geometrical product specifications — Surface texture designation