E43-031 · Taper and Angle Fit Errors · Mould Locating Taper Pin · ★★
Taper pin 1:50 used in place of 1:100; locating clearance 0.03; 20 parts reworked per month
[Wrong Taper] 1:50 was required but a 1:100 taper pin was used; for the same axial clamping displacement the radial clearance was twice as large.
[Loose Location] Poor cone contact let the assembly shift 0.03 relative to the fixture, so repeatability drifted.
[Design Omission] The taper should be called out and checked with a taper gauge, and the cone angle tolerance was not controlled.
1) Correct the taper pin to 1:50 to guarantee self-locking location;
2) Check with a taper gauge and require ≥80% contact to prevent loosening;
3) Call out the cone angle tolerance to control accuracy;
4) Calibrate the axial clamping displacement to preserve preload;
5) Ensure the cone surfaces are undamaged so contact is sound;
6) Measure locating clearance on the first piece to verify tightness;
7) Verify repeatability to confirm consistency;
8) Bring taper inspection into the acceptance criteria.
GB/T 117-2000 Taper Pins