E43-662 · Taper and Angle Fit Error · A fan taper shaft-hub designed for 8mm press-in travel but actually only 5mm, leaving insufficient interference and hub slip under high torque · ★★★★
The taper shaft-hub assembly pressed in only 5mm (designed 8mm); the cone interference was insufficient, the hub slipped circumferentially under rated torque, and the keyway was crushed.
[Mechanism] Taper fits develop radial interference by axial press-in to transmit torque; with insufficient press-in the interference is small, the friction torque is inadequate, and slip occurs.
[Calculation] For a 1:10 taper, a 3mm shortfall in press-in reduces radial interference by 0.3mm and cuts friction torque by 50%, below the transmitted torque.
[Design Omission] Press-in travel was poorly controlled, giving insufficient interference; design defect → hub slip.
1) Calculate the press-in travel from the taper and reach the designed 8mm;
2) Measure the axial press-in with a dial indicator;
3) Hold cone contact ratio ≥80% to ensure uniform interference;
4) Press in to a measured load with a hydraulic nut;
5) Test the first article for the slip torque;
6) Keep the cones clean and oil-free to prevent slip;
7) Mark press-in travel and interference on the drawing;
8) Verify by overload testing.
GB/T 1800.1-2020 Geometrical product specifications (GPS) - Limits and fits