E43-664 · Taper and Angle Fit Error · A hydraulic valve cone designed at 30°±4′ (AT7) but actually deviated 12′, collapsing sealing-cone contact to a line and causing internal leakage · ★★★★
The poppet cone angle deviated 12′ (required ±4′); the poppet and seat angles mismatched, contact collapsed to a line, sealing failed, and internal leakage ran 0.5L/min.
[Mechanism] Conical sealing requires matching cone angles to form an annular band of face contact; an angle mismatch degrades contact to a line, leaves the sealing band too narrow, and causes internal leakage.
[Calculation] The 12′ angle mismatch produces a 0.07mm gap over a 20mm cone generatrix, wider than the sealing contact band.
[Design Omission] The cone angle was machined to AT9 and went out of tolerance; design defect → line-contact sealing with internal leakage.
1) Control the cone angle tolerance per AT7 at ±4′;
2) Check the angle with a template or sine bar;
3) Lap and match the poppet and seat as a pair;
4) Hold the contact band ≥1mm wide and uniform;
5) Inspect the first article for cone angle and internal leakage;
6) Cone surface Ra≤0.4;
7) Mark the cone-angle AT grade on the drawing;
8) Verify by a pressure-seal test.
GB/T 11334-2005 Geometrical product specifications — Cone tolerances