E43-669 · Taper and Angular Fit Error · A fan V-belt pulley with design groove angle 38±30′ measured at 35°, causing the belt to wedge too deeply and slip at the bottom, lowering drive efficiency · ★★★
The V-belt pulley groove angle was 35° instead of the designed 38°; the belt wedged too deeply to the groove bottom, side contact decreased, the belt slipped, and fan speed dropped by 8%.
[Mechanism] A V-belt transmits power by wedging against the groove sidewalls; too small a groove angle lets the belt sink to the bottom, reduces sidewall normal force, and causes slipping from insufficient friction.
[Calculation] A 3° groove-angle error cuts belt-side contact pressure by 25%, so effective friction is below rated tension and the slip rate exceeds 2%.
[Design Omission] The pulley groove angle was turned out of tolerance, a design defect leading to belt slip and lower efficiency.
1) Turn the pulley groove angle to 38±30′ (per belt type);
2) Inspect the groove angle with a template;
3) Groove surface Ra≤3.2 to protect the belt;
4) Match the belt and pulley types;
5) On the first part, measure slip rate and speed;
6) Datum diameter must meet spec;
7) Mark groove angle and pitch diameter on the drawing;
8) Run-test to measure efficiency.
GB/T 10412-2002 Classical and narrow V-belt pulleys