E43-675 · Taper and Angular Fit Error · A taper bore checked with a plug gauge where blue contact 70% concentrated at the large end was misjudged acceptable, actual taper angle out of tolerance at AT9 · ★★★
The taper bore was checked with a taper plug gauge; 70% contact concentrated at the large end was wrongly judged acceptable, while the actual taper angle was out of tolerance at AT9 (required AT7), causing high toolholder runout.
[Mechanism] Taper gauges require both uniform contact ratio and axial location within the marked lines; checking only contact ratio without position misses taper-angle error.
[Calculation] Contact biased to the large end means the bore angle is too large; plug-gauge axial displacement beyond ±0.4mm corresponds to the angle slipping from AT7 to AT9.
[Design Omission] Gauge inspection judged only contact ratio without controlling axial displacement, a design defect leading to missed taper-angle error.
1) Use a taper gauge to check contact ≥80%, biased toward the small end;
2) Keep plug-gauge axial insertion within the marked lines;
3) Blue contact uniform and continuous;
4) Regrind out-of-tolerance bores;
5) On the first part, recheck taper angle on a CMM;
6) Calibrate gauges periodically;
7) Mark inspection criteria on the drawing;
8) Verify runout with the matched tool.
GB/T 11852-2003 Tolerances and specifications for cone gauges