E43-677 · Taper and Angular Fit Error · A pump-shaft taper locator with design impeller axial position ±0.1 measured at 0.4mm offset, causing uneven impeller-to-casing clearance and efficiency loss · ★★★
The taper-located impeller was axially off by +0.4mm, shifted from design position; front/back clearance with the pump casing was uneven (0.2/0.8mm), and pump efficiency dropped 6%.
[Mechanism] The axial position of a taper fit is set by insertion depth; pressing too deep shifts the impeller axially and disturbs flow-passage clearance.
[Calculation] A 0.4mm insertion error on a 1:16 taper changes radial interference, pushing impeller axial locating beyond ±0.1mm and shifting clearance by 0.6mm.
[Design Omission] No locating shoulder controlled taper insertion, a design defect leading to axial-position error.
1) Add an axial locating shoulder or stop to the taper fit;
2) Measure impeller axial position with a dial indicator;
3) Control the press-in amount within tolerance;
4) Balance front and back clearances;
5) On the first part, measure axial position and efficiency;
6) Taper contact rate ≥80%;
7) Mark axial-position tolerance on the drawing;
8) Run-test to measure efficiency.
GB/T 1800.1-2020 Geometrical product specifications (GPS) - Limits and fits