E43-685 · Taper and Angular Fit Error · A gear-grinding taper mandrel with design expansion contact ≥85% measured at 60%, causing 0.03mm blank locating eccentricity and out-of-tolerance ring runout · ★★★★
The taper mandrel expanded at only 60% contact; the gear blank located 0.03mm eccentric, and the ground gear showed 0.04mm out-of-tolerance radial ring runout with loaded mesh bias.
[Mechanism] A taper mandrel centers by cone expansion; low contact makes expansion uneven, offsets the blank, and shifts the machining datum.
[Calculation] 60% contact lowers centering accuracy; 0.03mm blank eccentricity amplifies through grinding to 0.04mm ring runout.
[Design Omission] Mandrel cone contact was low, a design defect leading to locating eccentricity and runout.
1) Lap the mandrel cone to ≥85% contact;
2) Check by bluing that contact is evenly distributed;
3) Mandrel runout ≤0.005mm;
4) Blank bore-to-mandrel fit meets accuracy spec;
5) On the first part, measure ring runout;
6) Expansion force uniform;
7) Mark contact ratio on the drawing;
8) Gear-grinding verification.
GB/T 11334-2005 Conical tolerances