E43-687 · Taper and Angle Fit Error · Drill-rod double-taper joint where an uncleared step at the transition between the 1:8 and 1:16 tapers caused insertion sticking and damage to the sealing cone · ★★★
On a drill-rod double-taper joint, a 0.1mm residual step remained at the transition between the 1:8 and 1:16 tapers; during mating the step butts first, the tapered faces cannot fully seat, and the sealing cone is damaged.
[Mechanism] A double-taper joint requires a smooth transition between the two tapered faces; if the transition step is not cleared, the step contacts first during mating, prevents the tapered faces from seating, and damages the seal.
[Calculation] The 0.1mm transition step creates a 0.1mm gap between the tapered faces, locally overloading and crushing the sealing cone and causing internal leakage.
[Design Omission] The double-taper transition was not rounded or relieved at the root; the design defect leads to sticking and cone-face damage.
1) Round and relieve the double-taper transition so there is no step;
2) Use a profilometer to verify a smooth transition;
3) Lap the tapered faces together to a contact rate ≥80%;
4) Trial-mate and insert without sticking;
5) On the first article, check sealing and sticking;
6) Ensure each taper segment is accurate;
7) Specify the transition requirement on the drawing;
8) Verify sealing.
GB/T 157-2001 Series of tapers and taper angles