E43-697 · Taper and Angle Fit Error · Fixture conical locating pin designed half-angle 15° but measured 12°, biasing contact in the workpiece locating hole and giving a 0.05mm repeat-locating error · ★★★
The fixture conical pin had a half-angle of 12° (designed 15°); it did not match the workpiece locating hole’s taper angle, contact biased to one end, and the repeat locating accuracy was poor at 0.05mm.
[Mechanism] A conical locating pin centers by full contact between its taper and the workpiece hole’s taper; a mismatch biases the contact, destabilizes centering, and degrades repeat accuracy.
[Calculation] A 3° half-angle mismatch shifts the contact and shortens the effective centering length, giving a 0.05mm repeat-locating error that exceeds the 0.01mm requirement.
[Design Omission] The pin taper angle did not match the workpiece hole; the design defect leads to poor repeat locating.
1) Match the pin half-angle to the workpiece hole at 15°;
2) Check the contact rate ≥80% by bluing;
3) Inspect the taper angle with a template;
4) Harden the pin for wear resistance;
5) Measure repeat locating on the first article;
6) Keep the tapered surface Ra≤0.8;
7) Specify the taper-angle match on the drawing;
8) Verify repeat accuracy in batch.
GB/T 11334-2005 Conical tolerances