E43-706 · Taper and angle fit error · A taper bore checked by bluing where the Prussian blue layer was too thick, causing false contact, a misjudged 90% contact rate versus the actual 60%, and large assembly runout · ★★★
When checking the taper bore by bluing, the Prussian blue was applied too thick; the coating filled the microscopic gaps, creating false contact and a misjudged contact rate of 90%, whereas the true rate was only 60%, with tool-setup runout of 0.02mm.
[Mechanism] The bluing method relies on a thin film to reveal the true contact spots; when the coating is too thick it fills the gaps, creating false contact and masking the low contact rate, leading to misjudgment.
[Calculation] A 0.02mm thick coating fills the taper gaps; the false contact reads 90% while the actual contact is 60%, a 30% discrepancy.
[Design Omission] No specification governs coating thickness in the bluing operation; this design defect → leads to a misjudged contact rate.
1) Apply the Prussian blue thin and even (about 2~3μm);
2) Lap the mating parts several times and read the stable contact pattern;
3) Supplement with axial-position interpretation using a taper test mandrel;
4) On the first article, measure and verify tool-setup runout;
5) Standardize the bluing procedure;
6) When needed, recheck on a CMM;
7) State the contact-rate acceptance criterion on the drawing;
8) Verify after assembly.
GB/T 1443-2016 Morse taper shank tools for machine tools