E43-713 · Thread tolerance and fit error · An M20 internal thread in a pump body whose designed pitch diameter 18.376+0.28 (6H) measured 18.85, over the upper limit, so it mated too loosely with the stud and stripped under load · ★★★★
The M20 internal thread had a pitch diameter of 18.85, exceeding the 6H upper limit by 0.19mm; the clearance with the 6g stud was too large, few flanks carried load, and under axial load the flanks slipped and stripped.
[Mechanism] Threads transmit load through flank contact; an oversize pitch diameter increases the internal-to-external flank clearance, reduces the effective contact area, and the loaded flanks slip and strip.
[Calculation] A pitch diameter 0.19mm over the upper limit widens flank clearance, cuts the effective engaged thread height by 30%, lowers tensile capacity, and causes stripping under axial load.
[Design Omission] Tapping pitch diameter was out of control; this design defect → causes a loose fit and stripping.
1) Hold the tapped pitch diameter within the 6H tolerance of 18.376~18.66;
2) Check the pitch diameter with GO/NO-GO plug gauges;
3) Select taps of suitable accuracy and replace them on time;
4) On the first article, check mating tightness and load capacity;
5) Verify the tapping pilot-hole diameter meets spec;
6) Use cutting fluid when tapping;
7) State the 6H tolerance on the drawing;
8) Verify with a pull-off test.
GB/T 197-2018 General-purpose metric screw threads — Tolerances