E43-726 · Thread Tolerance and Fit Error · An internal thread rejected because the plug-gauge GO end would not screw in, actually caused by a bruised gauge burr that misjudged many good parts as defective · ★★★
On inspecting an internal thread, the plug-gauge GO end would not screw in and the part was rejected; rechecking showed the gauge's first thread was bruised with a burr that jammed it - the part was not out of tolerance, and good parts were wrongly sent back.
[Mechanism] The plug-gauge GO end should screw freely into an acceptable thread; a bruise or burr on the gauge itself can jam it and cause good parts to be misjudged.
[Calculation] A 0.05mm burr on the gauge's first thread jams the entry, so it will not screw in and acceptable parts are misjudged as out of tolerance and wrongly rejected.
[Design Omission] The bruised gauge was neither inspected nor repaired - a design defect leading to misjudgment and wrongful rejection.
1) Before use, check the gauge's starting threads for bruises or burrs;
2) Periodically verify and calibrate the gauges;
3) Store gauges in a dedicated case to prevent bumps;
4) Recheck misjudged parts for confirmation;
5) Clear chips and deburr the workpiece threads;
6) Standardize the inspection procedure;
7) Maintain a gauge log;
8) Recheck by mating.
GB/T 3934-2003 Gauges for general-purpose screw threads — Technical specifications