E43-730 · Thread Tolerance and Fit Error · A stud's screw-in end designed with an interference thread had too much interference, pushing the entry torque over the limit and seizing and twisting off the stud in the hole · ★★★
The screw-in end of a stud used an interference thread with too much interference; on entry the flank interference sent the torque spiking, the stud seized in the tapped hole, and forcing it further twisted the stud off inside the hole.
[Mechanism] Interference threads rely on flank interference to resist loosening; too much interference makes the assembly friction torque exceed the stud strength, seizing and twisting it off.
[Calculation] Over-design interference raises the assembly torque to the stud's yield torque, so it seizes and cannot be driven in or out, and twists off.
[Design Omission] The interference-thread interference was set too high - a design defect leading to seizing and fracture.
1) Hold the interference-thread interference within a moderate, per-standard range;
2) Inspect the screw-in thread with a dedicated gauge;
3) Apply an anti-seize compound on assembly;
4) On the first article, measure entry torque;
5) Control the drive-in speed;
6) Check the stud material strength;
7) Call out interference on the drawing;
8) Verify assembly.
GB/T 1150-2004 Studs