E43-741 · Thread Tolerance and Fit Error · A batch of internal threads gauged with a worn NO-GO gauge let oversize pitch-diameter threads pass and left an over-loose fit · ★★★
On internal threads, the NO-GO gauge wore and its OD shrank; it could now screw into threads whose pitch diameter exceeded the upper limit, which were still passed, letting out-of-tolerance parts in and leaving an over-loose fit after assembly.
[Mechanism] The NO-GO gauge should not enter an acceptable thread (it limits the pitch-diameter upper bound); a worn, smaller gauge lets out-of-tolerance threads enter it, missing the rejection.
[Calculation] A 0.02mm wear on the NO-GO gauge loosens the acceptance upper bound; parts 0.02mm over the pitch-diameter upper limit are wrongly accepted and the fit is too loose.
[Design Omission] The worn NO-GO gauge was never reverified - a design defect letting out-of-tolerance parts in.
1) Periodically verify and calibrate thread NO-GO gauges;
2) Scrap and replace worn NO-GO gauges;
3) Use GO and NO-GO gauges together;
4) Recheck first articles by the three-wire method;
5) Set up gauge life-cycle management;
6) Store NO-GO gauges to prevent bumps;
7) State the inspection acceptance criteria in the process sheet;
8) Sampling-inspect at assembly.
GB/T 3934-2003 Gauges for general-purpose screw threads — Technical specifications