E43-755 · Thread Tolerance and Fit Error · A base tapped hole 1.5° out of perpendicular makes the bolt enter skewed, seat unevenly, and add bending stress · ★★★
The axis of a tapped hole in a base deviated 1.5° from perpendicular to the datum face. The bolt entered skewed, the bolt head did not seat flat on the bearing face, tightening introduced an additional bending stress, and the bolt was prone to fatigue fracture.
[Mechanism] Poor tapped-hole perpendicularity skews the bolt axis; the bolt head contacts on one side only, tightening adds a bending moment, and the bolt undergoes bending fatigue.
[Calculation] A 1.5° perpendicularity error leaves the bolt head contacting on one side, raises the tightening bending stress by 30%, and shortens fatigue life.
[Design Omission] The machined tapped hole was out of perpendicular — a process defect leading to a skewed, bent bolt.
1) Ensure axis perpendicularity when drilling and tapping;
2) Use a drill jig for guidance, or tap on a machining center;
3) On first articles, measure tapped-hole perpendicularity;
4) Keep the bolt-head bearing face flat;
5) If needed, use a spherical washer to compensate;
6) Center the tapping tool;
7) State the perpendicularity requirement on the drawing;
8) Verify loaded assembly.
GB/T 1184-1996 Geometrical tolerancing—Unsigned tolerances for linear and angular dimensions