E43-760 · Thread Tolerance and Fit Error · Pump inlet/outlet flange bolts at 8g are too loose, and under running vibration the nuts back off, losing preload and leaking the flange · ★★★
The pump flange bolts were fitted at 8g, which was too loose. Under running vibration the flanks micro-slid, the nut gradually backed off, the preload was lost, and the flange face leaked.
[Mechanism] In vibrating service an over-loose thread fit lets the flanks micro-slide; the nut's lateral micro-displacements accumulate into back-off, losing preload and causing leakage.
[Calculation] An 8g fit has a small pitch diameter and large clearance; under vibration the flank micro-slides by 0.5× the clearance, the nut backs off every 10,000 cycles, and the preload decays.
[Design Omission] At the vibrating point the thread fit was too loose with no anti-loosening — a design defect leading to vibration back-off and leakage.
1) Use a 6g thread fit at vibrating points to reduce clearance;
2) Add anti-loosening (nylon lock nut / lock washer / double nut);
3) Tighten by the turn-of-nut method;
4) On first articles, measure back-off under vibration;
5) Inspect threads with GO/NO-GO gauges;
6) Check preload on schedule;
7) State the fit and anti-loosening on the drawing;
8) Verify sealing under running.
GB/T 197-2018 General-purpose metric screw threads — Tolerances