E43-252 · Rolling Bearing Fit Errors · Circulating Water Pump 6308 Bearing Outer Ring ∅90, designed K7 interference 0.01, wrongly selected G7 clearance 0.010~0.035 · ★★
The outer ring rotated in the housing and crept; after 300 hours the bore had grown 0.15mm, with abnormal noise and vibration
[Mechanism] A rotating outer ring with a fixed housing requires an interference fit; selecting G7 left no interference, so the outer ring crept under radial external load.
[Calculation] The contact pressure p=δE/d; the designed K7 (δ=0.01) gives p=0.01×2.1e5/90=23MPa; with the G7 clearance δ is negative and p=0, so after 300 hours the outer ring wore the bore 0.15 out of round.
[Design Omission] A rotating outer ring should use K7/M7 interference, but a clearance was selected; this design flaw caused the outer ring to creep.
1) Change the housing bore to K7 to guarantee interference 0.005~0.02 so that p≥15MPa;
2) Add an anti-rotation pin to the outer ring;
3) Rough and finish bore the bore to guarantee roundness ≤0.01;
4) Select the 6308/C3 clearance class;
5) Measure the vibration ≤2.8mm/s after installation;
6) Specify bore surface Ra0.8 to reduce wear;
7) Listen for abnormal noise periodically;
8) Bring the housing bore tolerance onto the drawing.
GB/T 275-2015 Rolling Bearings — Fits with Shafts and Housings