E43-256 · Rolling Bearing Fit Errors · Induced Draft Fan Bearing 6316 ∅80, designed clearance C4 (0.06~0.09), wrongly selected C0 (0.02) · ★★
At a 60℃ temperature rise the shaft extended 0.06, consuming the clearance and locking the bearing
[Mechanism] With too little clearance there was nothing to absorb the thermal expansion and the rollers locked.
[Calculation] A 60℃ rise extended the shaft by Δl=αlΔT=12e-6×800×60=0.058≈0.06mm, consuming the C0 clearance of 0.02 and locking the bearing.
[Design Omission] A larger C3/C4 clearance class was not selected; this design flaw caused the lock-up.
1) Change to the larger C4 clearance 0.06~0.09 to leave room for thermal compensation;
2) Control the temperature rise ≤80℃;
3) Provide an axial expansion end;
4) Use thin oil circulation cooling;
5) Check the clearance before installation;
6) Monitor the temperature by infrared;
7) Lubricate regularly;
8) Bring the clearance into the selection table.
GB/T 4604.1-2012 Rolling Bearings — Internal Clearance