E43-258 · Rolling Bearing Fit Errors · Gearbox Tapered Roller Bearing 32212 Housing Bore ∅110, taper designed 1:12, actual 1:20 · ★★
The bearing was skewed by 0.05 and the rollers were unevenly loaded
[Mechanism] The wrong bore taper meant the outer ring could not be fully seated and was tilted.
[Calculation] The taper difference (1:12 versus 1:20) produced an axial seating difference Δ=0.05/(1/12-1/20)=3mm, so the outer ring tilted 0.05 and the rollers were unevenly loaded.
[Design Omission] The 1:12 taper was not specified; this design flaw caused the skew.
1) Change the housing bore taper to 1:12 so the outer ring seats fully;
2) Match with a taper gauge;
3) Mark the fully seated position after pressing;
4) Provide axial location for the outer ring to prevent tilting;
5) Inspect the tilt ≤0.02 after installation;
6) Run in and listen for abnormal noise;
7) Check the temperature rise;
8) Bring the taper onto the drawing.
GB/T 283-2007 Rolling Bearings — Tapered Roller Bearings