E43-269 · Rolling Bearing Fit Errors · Vertical Gearbox Bearing 6210 Outer Ring ∅90, designed K7 interference 0.02, actual -0.01 creeping · ★★
The housing bore ∅90 had an interference of -0.01mm (should be 0.02), so the outer ring crept and after 500 hours the bore was scored 0.2
[Mechanism] The insufficient interference let the outer ring micro-move relative to the bore, causing wear and scoring.
[Calculation] The contact pressure p=δE/d=-0.01×2.1e5/90=-23MPa (negative), so p=0 and the creep rate v∝load; after 500 hours the bore was scored 0.2.
[Design Omission] The K7 housing bore was not controlled; this design flaw caused the creeping.
1) Change the housing bore to K7 interference 0.005~0.02 to prevent creeping;
2) Add an anti-rotation feature to the outer ring;
3) Finish bore the bore to guarantee roundness;
4) Select 6210/C3;
5) Inspect the interference after installation;
6) Run in and listen for abnormal noise;
7) Check the temperature rise;
8) Bring the fit onto the drawing.
GB/T 275-2015 Rolling Bearings — Fits with Shafts and Housings